Client: |
|
Address: |
|
Property Description: |
(2) story single family home |
Property age/ size: |
Built 2012, 3,439 s.f. per listing |
Occupancy Status: |
Staged |
Inspection Date: |
01/28/2012 |
Inspection Time: |
12:00 P.M. – 2:30 P.M. +- |
Weather Conditions: |
Overcast, 40 deg F +-
|
Table of Contents
Summary of Inspection....................................................................................................... 3
Electrical System................................................................................................................. 5
Plumbing System................................................................................................................. 7
Heating System................................................................................................................... 8
Water Heater..................................................................................................................... 10
Site..................................................................................................................................... 12
Building Exterior............................................................................................................... 13
Crawlspace........................................................................................................................ 16
Garage............................................................................................................................... 18
Dining Room and Den...................................................................................................... 19
Kitchen and Nook............................................................................................................. 20
Great Room....................................................................................................................... 22
Powder Room.................................................................................................................... 24
Hallways............................................................................................................................ 25
Master Bedroom Suite....................................................................................................... 27
Bedrooms 2, 3, and 4........................................................................................................ 29
Bonus Room...................................................................................................................... 30
Main Bathroom.................................................................................................................. 31
Utility Room...................................................................................................................... 32
Attic................................................................................................................................... 33
Structural Pest Inspection Diagram................................................................................... 34
All items listed in the Summary of each section are listed below. Additional comments may be written in the body of the report. Please read the entire report. All items listed below should be further evaluated, inspected, modified, and/or corrected by a licensed professional in that corresponding or related trade.
WDO refers to “Wood Destroying Organism” as defined by the Washington State Department of Agriculture
- Items in this font are general comments throughout report.
- Items in this font are considered a minor cost and/or cosmetic.
- Items in this font are considered a substantial cost or an extreme safety concern.
Electrical System
- Breaker # 6 is double tapped
- Breaker lockout is not installed (lying at the base of the panel box)
Plumbing System
Heating System
- Furnace did not activate for 10 minutes +- when initially set to “hold, 80 degrees”. Recommend investigation by a licensed heating contractor
- Furnace filter is dirty and should be replaced
Water Heater
Site
- Front left corner of structure in contact with ground (WDO conducive condition). Recommend 4-6” separation between ground and structure
- Rear yard plantings adjacent to xxxth Ave. S.E. are not all vertical
Building Exterior
- Finish touch up at board beneath the rear sliding glass door
- Secure and trim as needed roofing above the entryway fascia
- Kick out flashing at the rear of the garage should slope downwards to fully drain the corner
- Leak from gutter at the front left corner of the garage
Crawlspace
- Waste line cap is not installed near the outfall (beneath the Den)
- Floor trusses do not have proper separation from concrete foundation walls in several locations. Recommend wrap ends of trusses with plastic sheeting. WDO conducive condition
Garage
Dining Room and Den
Kitchen and Nook
- Damage to interior of a drawer at far right side from the sink
- Bottom drawer at far left side from sink is not secure (falls out when opened)
- Gas piping hole beneath the cooktop should be sealed at the subfloor level and at the cabinet interior. The subfloor level should be sealed with steel wool or other to prevent rodents. Rodents will chew thru expansion foam
- Re-caulk backsplash to countertop as needed
- Refrigerator rollers should be locked if possible
Great Room
- Install batteries in fireplace for ignition during a power outage
Powder Room
- Doorstop missing
- Mark on the exterior (lower area) of the door
Hallways
- Clean ceiling adjacent to air duct grill outside of Utility room
- Question: Is the alarm system included with the home ? The alarm keypad near the entryway is in an impractical location; inside the far left side of the coat closet where it will be buried behind hanging coats
- Substantial gap beneath baseboard at stairs. Purchaser has requested this area be filled. A suggestion would be a very thin type of scribe molding painted white
Master Bedroom Suite
- Bump beneath carpeting to left of bed
- Stain on tile to left of toilet (circular pattern)
- Tub spout is loose. Straighten and tighten tub spout
Bedrooms 2, 3, and 4
- Electrical plate cover missing at East bedroom (behind the door)
- Door at South (front) bedroom self closes
- Closet door at South (front) bedroom is warped and binds with the door jamb
Bonus Room
Main Bathroom
- Re-caulk the backsplash to the countertop
- Rust stains at the inside of the bathtub
Utility Room
- Switch to fan is upside down. Plate cover screw missing
- Single hung window springs are not attached
Attic
|
|
|
No evidence of over heating |
|
|
|
Service
|
|
Type: |
Underground |
Meter Location: |
Side of garage |
Voltage: |
240 |
|
|
|
|
Panel
|
|
Location: |
Garage |
Manufacturer: |
Square D |
Type: |
Dual bus bar |
Panel Rating: |
200 AMP |
Main Disconnect: |
200 AMP |
Serv. wire Size/ Rating: |
200 AMP |
Sub-panel: |
No |
Grounding: |
EUFER grounding, limited visibility |
Panel Clearance: |
30” wide, 3’ in front as required |
|
EUFER grounding |
|
|
|
|
|
Breakers/ Wiring
|
|
Type: |
Copper romex |
Breakers: |
|
|
- Breaker lockout is not installed (lying at the base of the panel box) |
|
Breaker # 6 is double tapped |
|
Breaker lock out part |
|
|
|
Domestic Water
|
|
Supply: |
Public water per listing, not included in this inspection |
Supply Pipe: |
Poly pipe where visible |
House Piping: |
Pex type where visible |
Pipe Condition: |
Satisfactory where visible |
Main Water Shut off: |
@ garage
|
|
Domestic Water Shut off |
|
Front hose bib winter shut off |
|
|
|
|
|
Sanitary Sewer
|
|
Discharge: |
Public sewer per listing, not included in this inspection |
House Piping: |
ABS where visible |
Pipe Condition: |
Satisfactory where visible |
|
|
|
Furnace
|
|
Location: |
Garage |
Make/ Model: |
York |
Fuel Type: |
Natural gas |
BTUH Input: |
100,000 |
BTUH Output: |
95,000 |
Efficiency Rating: |
High-efficiency |
|
|
|
|
Useful Life
|
|
Est. Useful Life new: |
25 years |
Est. age of furnace: |
< 1 year |
|
|
|
|
Heat Exchanger |
|
Visible Inspection: |
No visible defects, limited visibility |
Gas detection test: |
No gas leak detected |
Burner test: |
No burner irregularities detected |
|
|
|
|
Operation |
|
Thermostat: |
Programmable @ floor 1 hall |
|
|
Disconnect: |
Switch on furnace |
Combustion Air: |
Appears adequate |
Filter: |
Located below furnace |
|
- Furnace filter is dirty and should be replaced
|
|
Furnace filter location |
|
|
|
|
|
Flue/ Gas Piping |
|
Flue Secure: |
Inspected |
Flue clearances: |
Per requirements where visible |
Gas Piping: |
Drip leg installed |
|
|
|
|
Heat Gain
|
|
Rating: |
35-65 deg F |
@ return air: |
74 deg F |
@ nearest register: |
128 deg F |
Heat Gain: |
54 deg F. Heat gain is within specifications of furnace
|
|
Temperature measured at return air |
|
Temperature measured at heat register |
|
|
|
|
Water Heater
|
|
Location: |
Garage |
Make/ Model: |
Rheem s/n RHLN0711VD537 manufactured 07/2011 |
Fuel Type: |
Natural gas |
Capacity: |
50 gallon |
|
|
|
|
Useful Life
|
|
Est. Useful Life new: |
12 years |
Est. age of heater: |
1 year +- |
|
|
|
|
Safety
|
|
TMP valve: |
As per required |
Earthquake Straps: |
Installed |
Expansion Tank: |
Installed |
Flame Rollout: |
No visible evidence |
|
Expansion tank is functioning as designed (hot water has not filled the expansion tank) |
|
|
|
|
|
Flue
|
|
Secure: |
Inspected |
Clearances: |
As required where visible |
Draft Hood: |
Inspected |
|
|
|
|
Water Temperature
|
|
Safe water temperature: |
120 deg F per industry standards |
Measured temperature: |
- Not measured |
|
|
Site
|
|
Grade at structure: |
Adequate grade away |
Earth to wood contact: |
|
Vegetation contact: |
Negligible |
|
- Rear yard plantings adjacent to xxxth Ave. S.E. are not all vertical |
Roof drain discharge: |
Underground discharge |
|
Corner of the driveway should be supported so that the vertical side is stable and a 4” minimum separation to the corner trim board can be achieved and maintained |
|
Trees are not all vertical |
|
|
|
|
|
Driveway
|
|
Type: |
Concrete |
Condition: |
Satisfactory |
Trip Hazard: |
None |
|
|
|
|
Front walks/ steps
|
|
Type: |
Concrete |
Condition: |
Satisfactory |
Trip Hazard: |
None |
|
|
|
|
Rear walks/ steps
|
|
Type: |
Concrete |
Condition: |
Satisfactory |
Trip Hazard: |
None |
|
|
|
|
Miscellaneous
|
|
Overhead Power Lines: |
N/A |
Retaining Walls: |
None that affect structure |
Underground Oil Tank: |
No visible evidence |
Irrigation System: |
Yes, not part of inspection |
|
|
General Condition
|
|
Structural Movement: |
No visible evidence |
Exterior doors: |
Satisfactory |
Windows (ext. cladding): |
Satisfactory |
|
|
|
|
Siding
|
|
Type: |
Hardboard type |
Condition: |
Satisfactory |
|
- Finish touch up at board beneath the rear sliding glass door |
Window/Door Flashing: |
Satisfactory |
Caulking: |
Satisfactory |
|
Incomplete touch up below the rear sliding glass door |
|
|
|
|
|
Roof
|
|
Estimated Pitch: |
Varies |
Material: |
Composition |
Layers: |
1+ |
How Inspected: |
From the street and rear yard |
Condition: |
Satisfactory |
|
- Secure and trim as needed roofing above the entryway fascia |
Ventilation: |
Eave and roof vents |
Plumbing Vents: |
Satisfactory |
Flues: |
Satisfactory |
Flashing: |
Satisfactory |
|
- Kick out flashing at the rear of the garage should slope downwards to fully drain the corner |
|
Kick out flashing should slope into gutter
|
|
Location of kick out flashing See image to left |
|
|
Secure roofing above entryway |
|
|
|
|
|
Gutters/ Downspouts
|
|
Type: |
Continuous metal |
Condition: |
|
Gutter leak |
|
|
|
|
|
Electrical
|
|
Outlets: |
Tested, GFCI protected |
Switches/Lights: |
Tested |
|
|
|
|
Plumbing
|
|
Hose Bibs: |
Anti-siphon |
Gas Piping: |
Inspected |
|
|
General
|
|
Visibility: |
Space is vacant |
Access location: |
Entry coat closet |
How viewed: |
Traversed entire crawlspace |
|
|
|
|
Moisture
|
|
Ventilation: |
Appears adequate |
Vapor Barrier: |
As required |
Moisture Intrusion: |
No visible evidence |
Sump Pump: |
None visible |
|
|
|
|
Structural
|
|
Foundation: |
No visible defects |
Mudsill: |
No visible defects |
Joists: |
No visible defects; limited visibility |
Post-Beams: |
Satisfactory |
Structural Movement: |
No visible evidence |
|
|
|
|
Insulation
|
|
Under-floor: |
Satisfactory |
Domestic Water Pipes: |
Satisfactory |
Heating Supply: |
Satisfactory |
|
|
|
|
Plumbing
|
|
Condition: |
Satisfactory |
|
- Waste line cap is not installed near the outfall (beneath the Den) |
Valves/ Other: |
None visible |
|
Water connection located beneath the garage |
|
Waste line cap not installed |
|
|
|
|
|
Electrical
|
|
Outlets: |
None visible |
Wiring/ junction boxes: |
No visible defects |
|
|
|
|
Heating/ Ventilation
|
|
Duct Work: |
n/a |
Ventilation Ducts: |
n/a |
Gas Piping: |
No visible defects |
|
|
|
|
Structural Pests
|
|
Conducive Material: |
|
Visible Evidence: |
No visible evidence |
|
Floor truss in near contact with concrete wall |
|
|
|
|
|
Nuisance Pests
|
|
Visible Evidence: |
No visible evidence |
Type: Attached |
|
|
General Room Condition
|
|
Visibility: |
Space is vacant |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
Satisfactory |
Slab: |
Satisfactory |
|
|
|
|
Safety
|
|
Fire separation: |
As required where visible |
Ignition point > above FF: |
In compliance |
Safety barricade to mech.: |
- Not needed |
|
|
|
|
Garage Door
|
|
Type: |
Metal roll-up |
Springs & Fasteners: |
No visible defects |
|
- Recommend removal of slide latches once door openers are installed |
Auto Reverse: |
n/a |
Photocell reverse: |
n/a |
Remote openers: |
n/a |
|
|
|
|
Electrical
|
|
Switches/Lights: |
Tested |
Outlets: |
All visible tested, GFCI protected |
|
|
|
|
Windows
|
|
Glazing: |
No visible defects |
Tempered: |
Not required |
Operation: |
Fixed |
|
|
|
|
Doors
|
|
Operation/latching: |
Tested |
Door condition: |
Satisfactory |
|
|
General Room Condition
|
|
Visibility: |
Rooms are staged |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
Satisfactory |
Flooring: |
Satisfactory |
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested |
|
|
|
|
Heating
|
|
Source: |
Ceiling register |
Air Flow/ Heat Gain: |
Satisfactory |
|
|
|
|
Windows
|
|
Glazing: |
No visible defects |
Tempered: |
Not required |
Operation: |
Tested |
Screen: |
No visible defects |
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
Location: Floor 1 |
|
|
General Room Condition
|
|
Visibility: |
Rooms are staged |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
Satisfactory |
Flooring: |
Satisfactory |
Cabinets: |
- Damage to interior of a drawer at far right side from the sink |
|
- Bottom drawer at far left side from sink is not secure (falls out when opened) |
|
|
Countertops: |
Satisfactory |
|
|
Gas piping hole beneath the cooktop Hole is visible to the crawlspace
|
|
Air leakage at hole beneath cooktop |
|
|
Damage to drawer interior |
|
|
|
|
|
Appliances
|
|
Dishwasher: |
Tested full cycle |
Dishwasher air gap: |
Visible |
Oven: |
Tested |
Cooktop: |
Tested |
Microwave: |
Not tested |
Ventilation: |
Tested |
Refrigerator: |
|
|
|
|
|
Plumbing
|
|
Functional flow: |
Appears adequate |
Hot/ Cold: |
Tested |
Drainage: |
Appears adequate |
Visible leaks: |
None visible |
Disposal: |
Tested |
Caulking: |
Satisfactory |
Fixtures: |
No visible defects |
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested, GFCI protected |
|
|
|
|
Heating
|
|
Source: |
Ceiling register |
Air Flow/ Heat Gain: |
Satisfactory |
|
|
|
|
Windows
|
|
Glazing: |
No visible defects |
Tempered: |
Not required |
Operation: |
Tested |
Screen: |
No visible defects |
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
|
|
General Room Condition
|
|
Visibility: |
Room is staged |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
Satisfactory |
Flooring: |
Satisfactory |
|
Infrared image of framing |
|
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested |
|
|
|
|
Heating
|
|
Source: |
Ceiling register |
Air Flow/ Heat Gain: |
Satisfactory |
|
|
|
|
Windows
|
|
Glazing: |
No visible defects |
Tempered: |
As required |
Operation: |
Tested |
Screen: |
No visible defects |
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
|
|
|
|
Fireplace
|
|
Type: |
Sealed gas direct vent |
Tested: |
Ignition tested |
|
- Install batteries in fireplace for ignition during a power outage |
|
|
General Room Condition
|
|
Visibility: |
Room is staged |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
Satisfactory |
Flooring: |
Satisfactory |
Cabinets: |
Satisfactory |
Countertops: |
Satisfactory |
Mirrors: |
Satisfactory |
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested, GFCI protected |
|
|
|
|
Heating
|
|
Source: |
Ceiling register |
Air Flow/ Heat Gain: |
Satisfactory |
Mechanical ventilation: |
Tested |
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
|
|
|
|
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
Bath Hardware: |
Satisfactory |
|
|
|
|
Plumbing
|
|
Functional flow: |
Appears adequate |
Hot/ Cold: |
Tested |
Drainage: |
Appears adequate |
Visible leaks: |
None visible |
Caulking: |
Satisfactory |
Toilet Secure: |
Satisfactory |
Fixtures: |
No visible defects |
Location: Floors 1 and 2 |
|
|
General Room Condition |
|
Visibility: |
Space is vacant |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
Satisfactory |
|
- Clean ceiling adjacent to air duct grill outside of Utility room |
Flooring: |
Satisfactory |
|
Insulation was not secured in position at the North side of the skylight. Insulation was placed back in position by inspector |
|
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested |
Smoke Detector: |
Yes |
|
|
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
|
|
Gap beneath the baseboard at the staircase |
|
|
|
|
|
Stairwell |
|
Handrails: |
As required |
Barricades: |
As required |
Balusters: |
As required |
Trip Hazard: |
None |
Location: Floor 2 |
|
|
General Room Condition
|
|
Visibility: |
Room is staged |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
Satisfactory |
Flooring: |
|
|
|
Cabinets: |
Satisfactory |
Countertops: |
Satisfactory |
Mirrors: |
Satisfactory |
|
Location of bump beneath carpeting |
|
Stain on tile to left of toilet |
|
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested. Bathroom outlets are GFCI protected |
Smoke detector: |
Tested |
|
|
|
|
Heating
|
|
Source: |
Floor register |
Air Flow/ Heat Gain: |
Satisfactory |
Mechanical ventilation: |
Tested |
|
|
|
|
Windows
|
|
Glazing: |
No visible defects |
Tempered: |
As required |
Operation: |
Tested |
Egress: |
Appears to meet current egress standards |
Screen: |
No visible defects |
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
Bath Hardware: |
Satisfactory |
|
|
|
|
Plumbing
|
|
Functional flow: |
Appears adequate |
Hot/ Cold: |
Tested |
Drainage: |
Appears adequate |
Visible leaks: |
None visible |
Caulking: |
Satisfactory |
Toilet Secure: |
Satisfactory |
Tub/Shower surround: |
Satisfactory |
Fixtures: |
Location: Floor 2 |
|
|
General Room Condition
|
|
Visibility: |
Rooms are staged |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
Satisfactory |
Flooring: |
Satisfactory |
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested |
|
- Electrical plate cover missing at East bedroom (behind the door) |
Smoke Detector: |
Tested |
|
|
|
|
Heating
|
|
Source: |
Floor register |
Air Flow/ Heat Gain: |
Satisfactory |
|
|
|
|
Windows
|
|
Glazing: |
No visible defects |
Tempered: |
Not required |
Operation: |
Tested |
Egress: |
Appears to meet current egress standards |
Screen: |
No visible defects |
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
|
|
|
- Closet door at South (front) bedroom is warped and binds with the door jamb |
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
Location: Floor 2 |
|
|
General Room Condition
|
|
Visibility: |
Room is staged |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
Satisfactory |
Flooring: |
Satisfactory |
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested |
Smoke Detector: |
- None |
|
|
|
|
Heating
|
|
Source: |
Floor register |
Air Flow/ Heat Gain: |
Satisfactory |
|
|
|
|
Windows
|
|
Glazing: |
No visible defects |
Tempered: |
Not required |
Operation: |
Tested |
Egress: |
Appears to meet current egress standards |
Screen: |
No visible defects |
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
Location: Floor 2 |
|
|
General Room Condition
|
|
Visibility: |
Room is staged |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
Satisfactory |
Flooring: |
Satisfactory |
Cabinets: |
Satisfactory |
Countertops: |
Satisfactory |
|
|
Mirrors: |
Satisfactory |
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
Outlets: |
All visible tested, GFCI protected |
|
- This GFCI outlet is the reset location for all of the bathrooms |
|
|
|
|
Heating
|
|
Source: |
Floor register |
Air Flow/ Heat Gain: |
Satisfactory |
Mechanical ventilation: |
Tested |
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
Bath Hardware: |
Satisfactory |
|
|
|
|
Plumbing
|
|
Functional flow: |
Appears adequate |
Hot/ Cold: |
Tested |
Drainage: |
Appears adequate |
Visible leaks: |
None visible |
Caulking: |
Satisfactory |
Toilet Secure: |
Satisfactory |
Tub/Shower surround: |
Satisfactory |
Location: Floor 2 |
|
|
General Room Condition
|
|
Visibility: |
Room is vacant |
Structural Movement: |
No visible evidence |
Moisture Infiltration: |
No visible evidence |
Walls: |
Satisfactory |
Ceiling: |
Satisfactory |
Flooring: |
Satisfactory |
Cabinets: |
Satisfactory |
Countertops: |
Satisfactory |
|
|
|
|
Electrical
|
|
Switches/Lights: |
All visible tested |
|
|
Outlets: |
All visible tested, GFCI protected |
|
|
|
|
Heating
|
|
Source: |
Floor register |
Air Flow/ Heat Gain: |
Satisfactory |
Mechanical ventilation: |
Tested |
|
|
|
|
Windows
|
|
Glazing: |
No visible defects |
Tempered: |
Not required |
Operation: |
|
Screen: |
No visible defects |
|
|
|
|
Doors/Millwork
|
|
Operation/latching: |
Tested |
Door condition: |
Satisfactory |
Millwork condition: |
Satisfactory |
|
|
|
|
Plumbing
|
|
Functional flow: |
Appears adequate |
Hot/ Cold: |
Tested |
Drainage: |
Appears adequate |
Visible leaks: |
None visible |
Caulking: |
Satisfactory |
Fixtures: |
No visible defects |
|
|
|
|
Appliances
|
|
Washer: |
n/a |
|
- Recommend install a drip pan with drainage to the exterior beneath the washing machine when installed |
Dryer: |
n/a Vented to outside |
Appliance Condition: |
n/a |
Location: Over main body of house |
|
|
General
|
|
Visibility: |
Space is vacant |
Access location: |
Master Bedroom closet and garage |
How viewed: |
Traversed North side of attic space and from garage access |
|
Attic space (typical) |
|
|
|
|
|
Moisture
|
|
Roof Ventilation: |
Appears adequate |
Moisture Intrusion: |
No visible evidence |
Bath/Kitchen fans : |
All vent to outside |
|
|
|
|
Structural
|
|
Structure Type: |
Manufactured trusses |
Sheathing: |
OSB |
Structural Movement: |
No visible evidence |
|
|
|
|
Insulation
|
|
Type: |
Blown in |
Condition: |
Satisfactory |
|
|
|
|
Flues/Vent Stacks
|
|
Plumbing Stacks: |
All vented to exterior |
Gas Flues: |
No visible defects |
|
|
|
|
Electrical
|
|
Wiring/ junction boxes: |
No visible defects |
|
|
|
|
Structural Pests
|
|
Conducive Material: |
No visible evidence |
Visible Evidence: |
No visible evidence |
|
|
|
|
Nuisance Pests
|
|
Visible Evidence: |
No visible evidence |
Wood Destroying Organisms (WDO) |
|
Conducive Conditions (CC) |
||
WDO-AB |
Anobid Beetles |
|
CC-BG |
Bare Ground |
WDO-CA |
Carpenter Ants |
|
CC-CD |
Conducive Debris |
WDO-DT |
Dampwood Termites |
|
CC-EM |
Excessive Moisture |
WDO-MA |
Moisture Ants |
|
CC-EW |
Earth-Wood Contact |
WDO-OB |
Other Beetles |
|
CC-FC |
Failed Caulking |
WDO-RF |
Rot Fungus |
|
CC-IV |
Inadequate Ventilation |
WDO-ST |
Subterranean Termites |
|
CC-RG |
Restricted Gutter |
|
|
|
CC-VC |
Vegetation Contact |
Inspection Conditions (IC) |
|
|
|
|
IC-CSA |
Crawl Space Access |
|
|
|
IC-IA |
Inadequate Clearance |
|
|
|
|